• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INSTALLATION
ASPSU - Test

TM-10-1670-265-12-P Tools List for High Altitude Airdrop Resupply System: 2 000 Pound Capacity Manual
Page Navigation
  29    30    31    32    33  34  35    36    37    38    39  
TM 10-1670-265-12&P
T.O. 13C7-1-21
SECTION VII.
MAINTENANCE PROCEDURES FOR ALTITUDE
SENSOR PARACHUTE STAGING UNIT (ASPSU)
4-16. ASPSU - Inspect
4-16
This task covers: Inspection
INITIAL SETUP
Personnel Required:
43E (10) Parachute rigger
Equipment Condition:
Para. 4-8 Sensor and cutter assembled.
NOTE:
The instructions pertain to the functional group number sequence 02 in the MAC and RPSTL.
INSPECTION
1. Insure that the cutter mechanism has not been fired.
(You should not be able to see the blade.)
2. Insure that the four captive screws are tight.
3.  Insure that the safety tag and pin assembly is
securely attached.
4. Inspect for dents, cracks, or foreign material.
END OF TASK