TM 10-1670-269-23&P    0013 00 0013 00-18 5.    Make second accordion fold by placing your left hand on the canopy, close to the end of pack tray on the right.  Fold the canopy so it is 1-inch over the pack tray on the right.  Extend the fold 1-inch over the right edge of the pack tray.  Remove packing weights as necessary.    Do not fold the apex under. 6.    Make the third and final accordion fold, adapting procedures in step 5., above.  Remove packing weight as necessary.  Center the apex sock on top of the folded canopy ensuring that the fold on the right is even with the previous fold. NOTE Ensure the upper lateral band is centered, minor adjustments to the second and third accordion folds may be made if necessary. 7.    Cut two 36-inch lengths of type III nylon cord (for use as pull-up cords) and remove core threads.   Pass one length through each of the locking loops on the pack tray canopy-staging flap. NOTE Canopy Folds Apex Sock Canopy Right Edge of Pack Tray