Figure 2-133 .   Locking Stow Loop Replacement Details
Figure 2-133.2.    Marking Modified G-12E Deployment Bag

TM-10-1670-281-23P Parachute Cargo Type: 64-Foot Diameter Model G-12D NSN 1670-00-893-2371 and Model G-12E NSN 1670-01-060-3705 Manual
Page Navigation
  198    199    200    201    202  203  204    205    206    207    208  
ARMY TM 10-1670-281-23&P AIR FORCE T.O. 13C5-32-2 NAVY NAVAIR 13-1-32 c.  Adjustment.  Modifying deployment bag for G-12E (1)    Enlarge each locking stow loop by cutting 3/4 to 1 1/2 inches of stitching on one end of the loop with your rigger's knife (figure 2-133.1). (2)    Insure  that  the  stitching  is  cut  only  on  one  end,  and  that  the  length  of  cut  stitching  does  not exceed 1 1/2 inches. (3)   Stencil “D-BAG  FOR  G-12E  ONLY”  on  the  riser  extension  protector  flap,  3  inches  from  the edge  of  open  end.  Stencil  1  -inch  letters  with  a  stencil  brush,  ink  and  a  stencil  marking  set (figure 2-133.2). Figure 2-133.1.  Enlarging Locking Stow Loops, G-12E Deployment Bag .   Change 3 2-180.1