EXTRACTION LINE PANEL   STOWING 60-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
Figure 2.  Wrapped Plies of Extraction Line Secured

TM-10-1670-286-20 Extraction Line Panel NSN 1670-01-183-2678 Manual
Page Navigation
  10    11    12    13    14  15  16    17    18    19    20  
TM 10-1670-286-20 EXTRACTION LINE PANEL                                                                                                                          0005 00 STOWING 60-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL 0005 00-2 Figure 1.  Layout for Extraction Line Panel and 60-FT. One Loop Extraction Line.         b.  Install 16 retainer bands 8 on upper and 8 on lower row of stow loops.         c.  Cut two 36-inch lengths of ½-inches wide tubular nylon webbing.  Fold each length in           half and girth-hitch one to 6th stow loop from the left of upper and lower row of stow loops.         d.  Cut four 6 x 16 inch pieces of cotton muslin cloth and four 36-inch lengths of ¼-inch           wide type I, cotton webbing and position at upper end of panel.           e.  Place 60-foot, one loop extraction line on pack table.  Locate and mark center point on extraction line.         f.  Place extraction line lengthwise on panel with center mark aligned with center row of stow loops.