TM 10-1670-287-23&P 0014 00 0014 00-45 c.     Verify that the ball of the power cable is correctly engaged with the piston rod. d.    Attach power-housing retainer to the AR2 finger tight.  Verify that the ball of the power cable is correctly engaged with the piston rod by looking through transparent cable seal retainer. e.    Ensure that the cable seal retainer is present (located just above the power housing retainer). f. Install the AR2 in the ripcord release pocket and close flap. 2.    For units utilizing the Automatic Ripcord Release (FF-2), install as follows: Power Cable Ball Piston Rod Power Cable Power Housing Retainer