TM 10-1670-292-23&P                                                       0026 00 0026 00-3 12.  Make two overhand knots in each control line against the bottom of each toggle.  The remaining free end of each control line from the second overhand knot is to measure five inches.  Then make the third overhand knot in the free end.  Trim the control line free end at a point ½-inch below the third overhand knot. 13.  For parachutes with more than five jumps, position the control line toggles as follows: a.    Undo the three overhand knots in each control line free end. b.    Again, position the toggle against the bottom of the guide ring and, while holding the toggle in position, pull both control line free-ends taut until the control line tension equals that of the suspension lines. c.    Secure the toggle by making two overhand knots against the bottom of the toggle.  After the toggle is secured with the two overhand knots, check to make sure the toggle does not exert any pressure against the guide ring, on the guide ring retaining strap that is connected to the parachute riser. 5 IN