TM 10-1670-299-20&P TO 14D1-2-470-2 NAVAIR 13-1-41 (6)  Forward End Securing Straps and Heavy Duty Adapters.  Replace damaged forward end securing straps (1) and heavy duty adapters (2) as follows: (a)  Remove damaged strap (1) by cutting along stitching (3) that secures strap to pack.  Replace strap with a length of Type X nylon webbing equal to the length removed. Replace damaged adapter (2) with serviceable adapter of the same type. (b)    Fold  the  webbing  around  the  heavy  duty  quick  fit  adapter  (2)  and  position  strap  (1)  on  the  pack  in  its original position, as shown.  Stitch with 3 inch three point WW pattern as shown (3) using size 5 thread, 5 to 7 stitches per inch and a type HD sewing machine. 2-139