CONTROL INTERLOCKS TEST
AR2 FUNCTIONAL TESTS TABLE - TM-10-1670-305-23P_88

TM-10-1670-305-23P Automatic Ripcord Release AR2 Model 451 NSN 1670-01-369-7914 Test Chanber Assembly AR2 Model 452 NSN 1670-01-370-0752 Manual
Page Navigation
  54    55    56    57    58  59  60    61    62    63    64  
TM 10-1670-305-23&P 0010 00-9 ELECTRONIC TEST CHAMBER ASSEMBLY, MODEL 453 0010  00 OPERATION UNDER USUAL CONDITIONS CONTROL INTERLOCKS TEST 19.  Press GO TO ALT AND DWELL switch (7). 20.  ALTITUDE DWELL indicator (6) shall flash.  DISPLAYS LOCKED indicator (18) shall remain illuminated and displays shall not reset. 21.  Wait until ALTITUDE DWELL indicator (6) stops flashing.  Set AR2 JUMP/OFF switch to JUMP.  Press FALL switch (9). 22.  The test chamber shall not indicate a fall. 23.  Press RESET DISPLAYS switch (17). 24.  ALTITUDE (FT MSL) display (20) shall reset to 3000 feet (value set previously).  FALL RATE (FT/SEC) display shall show approximately zero. 25.  Set AR2 JUMP/OFF switch to OFF. 26.  All interlocks and indicators shall function as described above or the test chamber is defective and must be returned to depot for repair.