Figure 1. Routing the Main Closing Loop, Closing Loop Under The Protective Cover, Main Closing
MAIN PACK TRAY STIFFENER GROMMETS REPAIR, REPLACE

TM-10-1670-327-23-P MC-6 Personnel Parachute System NSN 1670-01-527-7537 Manual
Page Navigation
  287    288    289    290    291  292  293    294    295    296    297  
TM 10-1670-327-23&P
0046 00
UNIT MAINTENANCE
MC-6 PERSONNEL PARACHUTE SYSTEM
NSN 1670-01-527-7537
MAIN PACK TRAY CLOSING PIN COVER
REPLACE
INITIAL SETUP:
Tools
Personnel Required
Sewing Machine, Medium Duty (Item 59, WP
92R (10) Parachute Rigger
0097 00)
Stitch Removal Tool (Item 62, WP 0097 00)
Materials/Parts
Equipment Condition
Thread, Nylon, Size E (Item 51, WP 0109 00)
Lay out on packing table or other suitable area.
REPLACE
1. Using a stitch removal tool, carefully remove the damaged pin protector flap.
2. Remove any loose stitching.
3. Center the new pin protector flap (figure 1, item 1) overlapping the binding tape at the end of the top
flap.
1
Figure 1. Replace Damaged Pin Protector Flap.
4. Using a medium duty sewing machine and size E nylon thread, 7 to 10 stitches per inch and 3/8 of an
inch wide, sew the pin protector flap to the binding tape.
END OF WORK PACKAGE