0011 00-3
2. Attaching the snap hook to the 15-foot USL configuration, or the 20-foot USL configuration.
a. Position the snap hook so the opening is facing outward. Lay the static line flat on the packing
table; ensure the green ID marking thread is on top and on the outside of the loop.
b. Pass the 3½-inch loop end of the static line through the opening in the base of the snap hook,
from bottom to top.
c. Pass the top of the snap hook through the static line loop.
d. Continue passing the snap hook through the static line loop; pull the excess static line back
through the opening in the base of the snap hook until the loop is past the snap hook opening.