TM 10-1670-280-23&P 0039 00
0039 00-2
d. Secure the buffer to the loop webbing by handtacking at three points according to the details in
illustration detailed below, using one turn double, ticket No. 8/7 waxed cotton thread at each tacking
point. Secure each of the tacking ends with a surgeons knot and locking knot. Trim tie ends to ½-
inch.
4. Restenciling. As required, restencil identification marks using the procedures in WP 0016 00, MARKING
AND RESTENCILLING.
REPLACE
Replace an unserviceable deployment bag bridle with a serviceable item from stock.
END OF WORK PACKAGE