TM 10-1670-292-23&P 0011 00
0011 00-41
2. Using a 14-inch length of type I, ¼-inch, cotton webbing, pass an end through the right bottom
connector link tie loop, ensuring the control lines are to the inside, through the right pair of connector
links, through the top right connector link tie loop, and through the cover tie loop.
3. Secure all tie loops and connector links together with a surgeons knot and a locking knot. Cut excess
webbing; leave the end approximately 2-inches long.
4. Secure the left tie loops and connector links using procedures in steps 2. and 3., above.