TM 10-1670-296-20&P 0058 00
UNIT MAINTENANCE
ANCILLARY EQUIPMENT FOR LOW VELOCITY AIR DROP SYSTEMS (LVADS)
INITIATOR SIMULATOR
0058 00-1
THIS TASK COVERS:
Inspect
Test
Replace
Tools
Power Supply, 28 VDC (Item 25, WP 0064 00)
Materials/Parts
Y-Connector (Item 1, WP 0101 00)
Box, Control (Item 1, WP 0104 00)
Cable, Power, 20-Foot (Item 1, WP 0110 00)
Personnel Required
92R (10) Parachute Rigger
Equipment Condition
N/A
References
WP 0005 00; WP 0007 00
INSPECT
Perform a technical/rigger type inspection of the initiator simulator in accordance with WP 0007 00 and WP
0005 00, Table 1.
TEST
Testing the initiator simulator.
1. Ensure the POWER and JETTISON switches of a serviceable control box are OFF. Connect P1 plug of a
serviceable 20-foot power cable to J1 receptacle of control box.
2. Connect the P2 plug of the power cable to the 28 VDC power supply.
3. Plug the 28 VDC power supply cord into the 115 VAC power source.
4. Turn the power supply ON. Ensure the control box circuit breaker is pushed in.
5. Connect J1 receptacle of initiator simulator directly into J3 receptacle of a serviceable Y-connector.
6. Connect J1 receptacle of Y-connector directly into J2 receptacle of control box.
7. Set circuit breakers on initiator simulator to ON.
8. Set POWER switch of control box to ON.
9. Set JETTISON SWITCH on control box to ON. If both circuit breakers on the initiator simulator are
tripped to OFF, the initiator simulator is serviceable. If either one or both breakers do not trip, the initiator
simulator is defective.