TM 9-1370-201-12
Figure 2-17. Launching flare by hand.
Section III. REMOVAL OF FLARE DISPENSER XM19 FROM HELICOPTER
2-7.
Removal of Dispenser
b.
Detach cable from firing panel and nitrogen
cylinder.
WARNING
c. Unlock snap-screws holding firing panel to
Prior to attempting any removal procedures,
instrument panel. Remove firing panel.
assure that safety valve handle is in SAFE
d. Retract snout.
position, that bail is under handle of firing
e. Loosen locking nut and turn vibration snubber
device, and that safety switch is in SAFE
screw counterclockwise to fully extended position.
position with cover down.
f. Manually move interlock handle away from rail
to disengage interlocks from dispenser assembly.
a. Assure that safety valve handle is in SAFE
position, that bail is under handle of firing device, and
that safety switch is in SAFE position with cover down.
2-17