ARMY TM 10-1670-281-23&P
AIR FORCE T.O. 13C5-32-2
NAVY NAVAIR 13-1-32
2-33.
Riser (cont).
(e)
Position the folded webbing length in the original buffer location and secure the webbing within
the attaching loop by handtacking at three points according in figure 2-126 and using the
procedures in (3), above.
4839-125
Figure 2-126. Clevis Attaching Loop Buffer Replacement Details.
b. Replace. Replace an unserviceable riser with a serviceable item from stock.
2-162