TM 10-1670-286-20
EXTRACTION LINE PANEL 0007 00
STOWING 60 FOOT SIX LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
0007 00-2
b. Cut seventeen 24-inch lengths of ¼-inch wide type I cotton webbing, fold in half and girth-hitch at even
spacing 8 each of ties to left and 8 each to right row of stow loops of bottom panel. Girth-hitch remaining tie
to center stow loop at upper edge of panel (figure 1).
c. Lay top panel aside for later use.
d. Cut 38-inch length of ½-inch tubular nylon webbing, fold in half and girth-hitch to first stow loop, center
row at lower edge of panel.
e. Cut two 8 x 16-inch pieces of cotton muslin cloth and two 36-inch lengths of ¼-inch wide type I cotton
webbing, position at the lower end of the bottom panel.
f. Place a 60-foot, six-loop extraction line at upper end of pack table.
g. Measure and mark point on extraction line 5-feet from one end (this will be load attaching end).
h. Route marking end of extraction line from upper end of panel to lower end, along center row of stow
loops, align 5-foot mark with lower edge of panel.
Figure 1. Bottom Panel Layout for Stowing 60-FT Six Loop Extraction Line.