TM 10-1670-286-20
EXTRACTION LINE PANEL 0010 00
STOWING 160-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
0010 00-2
Figure 1. One Panel Layout for Stowing 160 FT One Loop Extraction Line.
b. Install 51 rubber retainer bands on left and right row of stow loops (26 on left row and 25 on right row).
c. Cut a 36-inch length of ½-inch wide tubular nylon webbing. Fold in half and girth-hitch to 1st stow loop,
center row at lower edge of panel.
d. Cut two pieces of 6 x 16-inch cotton muslin cloth and two 36-inch lengths of ¼-inch wide type I cotton
webbing. Position at lower end of panel.
e. Place 160 foot one loop extraction line at upper end of pack table.
f. Measure and mark point on extraction line 5 feet from one end (This will be the load attaching end).
g. Route marked end of extraction line from upper end to lower end along center row of stow loops, align 5
foot mark with lower edge of panel.
2. Stow extraction line.
a. Separate and wrap each ply of extraction line with two 6 x 16-inch pieces of cotton muslin cloth at point
immediately above 5-foot mark on extraction line (figure 2).