TM 10-1670-286-20
EXTRACTION LINE PANEL 0010 00
STOWING 160-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
0010 00-4
b. Secure wrapped plies together at each end with two turns of single ¼-inch wide type I cotton webbing.
Tie with surgeons knot and locking knot.
CAUTION
The extraction line must be firmly secured to the panel to prevent
slippage and damage during deployment.
c. Pass running ends of 36-inch length of ½-inch tubular nylon webbing previously installed on panel up
between wrapped plies of extraction line, pass each running end in opposite direction down and under stow
loop and back to top of extraction line. Secure running ends on top of extraction line with surgeons knot,
locking knot, and overhand knot on running ends (figure 3).
Figure 3. Extraction Line Secured to Bottom Panel.
d. Beginning at lower left corner of panel, make first of S-fold/stow extraction line and secure with rubber
retainer band (figure 4).