2-41. Fixed Keepers.
This task covers:
Replace
Tools:
Equipment Condition:
Knife, Item 5, Appendix B
Inspected (paragraph 2-13)
Cleaned (paragraph 2-12)
Materials/Parts:
Laid on work table
Tape, Filament Reinforced, Type IV, 1-Inch Wide,
Item 16, Appendix D
NOTE
The 10 fixed keepers are located 18 Inches apart beginning at a point 29 Inches
from attaching loop ends.
Replace.
(1)
Remove original fixed keeper.
(2)
Apply tension to adapter web.
(3)
Wrap all 12 adapter webs with tape in original location, gummed side away from loops for two
wraps.
(4)
Reverse tape direction, gummed side toward loops for two wraps (figure 2-60).