TM 10-1670-327-23&P
0087 00
REPLACE - continued
b. Pass the 3-1/2-inch loop (figure 9, item 1) on the static line, through the 2-inch buffer loop
(figure 9, item 2) on the USL 5-foot extension.
1
2
Figure 9. Pass The 3-Inch Loop On The Static Line, Through The 2-Inch Buffer Loop.
c.
Pass the snap hook (figure 10, item 1) of the USL 5-foot extension through the 3-1/2-inch loop
(figure 10, item 2) on the static line.
2
1
Figure 10. Pass Snap Hook Of USL 5-Foot Extension Through Loop On Static Line.
0087 00-5