Figure 1.  Breakcord and Bridle Attached to the Parachute
Figure 3.  Extraction Parachute Attached to Extraction Line

TM-10-1670-286-20 Extraction Line Panel NSN 1670-01-183-2678 Manual
Page Navigation
  100    101    102    103    104  105  106    107    108    109    110  
TM 10-1670-286-20 EXTRACTION LINE PANEL PROCEDURES FOR C-17 GLOBEMASTER III                                   0017 00 ATTACHING THE 28-FOOT EXTRACTION PARACHUTE TO THE 140-FOOT, THREE   LOOP EXTRACTION LINE AND EXTRACTION LINE BAG 0017 00-3     3.  Replace Breakcord Tie.         a.  Slide safety loop from bent V-Ring and fold under the deployment bag.  Run pendulum line under           the deployment bag and through the safety loop.  Tie through the pendulum line attachment loop with           alternating half hitches and tape.             b.  Remove the temporary canopy breakcord tie installed during packing of the parachute.         c.  Cut an 18-inch length of type III nylon cord for use in replacing canopy breakcord tie.         d.  Route the type III nylon cord one turn single, through canopy bridle loop, around deployment bag         bridle loop straps and through connector link.  Secure tie with a surgeon’s knot, locking knot and           overhand knot in running end (figure 2). Figure 2.  28’ Extraction Parachute Secured to Extraction Line Bag. Deployment Bag Bottom Securing Loop Tie Strap Handle (Bottom Panel) Canopy Breakcord Tie V-Ring Parachute Attaching Web