TM 10-1670-296-20&P                                                       0018 00 0018 00-2 13. Do not re-cock the actuator arm until the latch linkage is reset manually to accept the engagement of the catch (dot and arrow align). WARNING When the cable assembly is installed to the actuator and latch assembly, avoid any unnecessary turning and twisting of the actuator or latch.  Damage to the inner cable construction may occur.  If these procedures and pre-cautions are not followed, damage may occur which could cause a possible malfunction. 14. If twisting and turning occurs during the pre-airdrop rigging, disconnect the cable assembly from the latch and actuator assembly and repeat the manual push/pull test as stated above. REPLACE 1.    Replace an unserviceable or missing straight-headed pin or ½-inch long cotter pin on either end of the cable with a serviceable item from stock. 2.    Replace an unserviceable 12-, 16-, 20-, 24-, 28-foot long cable assembly with a serviceable item from stock.   END OF WORK PACKAGE