TM 10-1670-268-20&P 0009 00
0009 00-2
CLEAN
1. Remove dirt, grease, and foreign material, using plain water or a solution of detergent and water.
Rinse with clean water.
2. Wipe dry with clean cloth.
3. Remove burrs by filing.
4. Remove corrosion with wire brush.
INSPECT
Inspect for wear, cracks, excessive corrosion, and deformation.
REPLACE
1. Replace parts that show any of the defects identified in INSPECTION above.
2. Replace extraction bracket assembly (1) if lug (2) does not move freely.
ASSEMBLE
1. Position lug (2) in frame (4).
2. Install the following parts in frame (4):
a. 2 bushings (5)
b. Bolt (6)
c. 2 flat washers (7)
d. Self-locking nut (10)
3. Using two 1½-inch wrenches, tighten self-locking nut (10) and bolt (6) and bottom out, then back off
self-locking nut (10) ½ turn. Ensure bolt (6) rotates freely within bushing (9).
4. Secure extraction bracket assembly (1) to platform using the following parts:
a. 4 self-locking nuts (3)
b. 8 flat washers (8)
c. 4 bolts (9)
5. Use punch to align bolt-holes in bracket with matching holes in platform panel.
6. Start bolts two or three turns by hand before using wrenches to fully tighten.
3
8
1
8
6
7
10
4
9
5
7
5
2
END OF WORK PACKAGE