TM 10-1670-286-20
EXTRACTION LINE PANEL 0002 00
UNIT MAINTENANCE INSTRUCTIONS FOR EXTRACTION LINE PANEL
0002 00-4
Table 1. Unit Preventive Maintenance Checks and Services
B-Before use
D-During use
A-After use
ITEM
NO.
INTERVAL
B D A
ITEMS
TO BE
INSPECTED
PROCEDURES
CHECK FOR AND HAVE SERVICED AS NECESSARY
1
2
3
4
5
6
X
X
X
X
X X
X X
X X
X X
Body
Reinforcement
Strap
Tie Strap
Strap Handle
Closing Strap
Closing Loop
Check for cuts, burns, abrasions, broken or missing
stitches. If any defects are found, replace
Extraction Line Panel.
Check for foreign substance. If any foreign substance
is found, clean as directed in WP 0003 00.
Check for illegible or missing identification markings
(Figure 1) which are part number, manufactures
name and date of manufacture. Stencil or mark
identification markings as required in WP 0004 00.
Check the three reinforcement straps for cuts, burns
abrasions, broken or missing stitches and from loops
at each end of each strap. If any defects are found,
replace Extraction Line Panel.
Check for foreign substance. If any foreign substance
is found, clean as directed in WP 0003 00.
Check the three tie straps for cuts, burns, abrasions,
broken or missing stitches and torn loops. There are
twelve loops in each tie strap. If any defects are
found, replace Extraction Line Panel.
Check for foreign substance. If any foreign substance
is found, clean as directed in WP 0003 00.
Check the four strap handles for cuts, burns,
abrasions, broken or missing stitches. If any defects
are found, replace Extraction Line Panel.
Check for foreign substance. If any foreign substance
is found, clean as directed in WP 0003 00.
Check the two closing straps for cuts, burns,
abrasions, broken or missing stitching and torn loops.
There are twenty-four loops in each closing straps. If
any defects are found, replace Extraction Line
Panel. Check for foreign substance. If any foreign
substance is found, clean as directed in WP 0003 00.
Check the six closing loops for cuts, tears, burns,
abrasions, broken or missing stitching. If any defects
are found, replace Extraction Line Panel.
Check for foreign substance. If any foreign substance
is found, clean as directed in WP 0003 00.