TM 10-1670-286-20
EXTRACTION LINE PANEL 0008 00
STOWING 120-FOOT SIX LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
0008 00-2
Figure 1. Panel Layout for Stowing 120 FT Six Loop Extraction Line.
b. Cut forty-eight 24-inch lengths of ¼-inch wide type I cotton webbing fold in half and girth-hitch 11 stow
ties to left and right row of stow loops on top and bottom panels. Install an additional stow tie to 1st, 6th and
12th stow loop on right of stow loop of top panel. Girth-hitch remaining stow tie to lower center stow loop of
top panel.
c. Lay the top panel aside for later use.