TM 10-1670-287-23&P
0013 00
0013 00-36
9. Reclose the container IAW the CLOSING CONTAINER procedure above. Reinsert the ripcord pin(s)
threading top pin through eye of power cable (detail A above).
10. After testing has been completed and the specified requirements are met, remove Parachute Log
Record from log record pocket on underside of ripcord pin protector flap and make required entries.
Reinsert log record into log record pocket. Close ripcord pin protector flap. Dress the container.
11. Rigger check number 7.
ATTACHMENT OF THE AR2 (Reserve Mounted AR2)
Attach the AR2 as follows:
1. Ensure that the AR2 JUMP/OFF switch is OFF.
OFF
JUMP/OFF
Switch