TM 10-1670-296-20&P 0012 00
UNIT MAINTENANCE
ANCILLARY EQUIPMENT FOR LOW VELOCITY AIR DROP SYSTEMS (LVADS)
MULTI-LOOP LINE
0012 00-1
THIS TASK COVERS:
Inspect
Repair
Replace
Tools
Knife, Pocket (Item 19, WP 0064 00)
Shear, Trimmer (Item 41, WP 0064 00)
Materials/Parts
Beeswax (Item 3, WP 0125 00)
Line, Multi-Loop (Item 2, WP 01066 00)
Tape, Pressure Sensitive, Type IV (Item 30, WP 0125 00)
Thread, Nylon, Size 6, OD (Item 31, WP 0125 00)
Thread, Nylon, Size FF, OD (Item 33, WP 0125 00)
Wax, Paraffin, Technical, Type I, Grade A (Item 34, WP 0125 00)
Webbing, Nylon, Type VIII (Item 36, WP 0125 00)
Webbing, Nylon, Type XXVI (Item 37, WP 0125 00)
Personnel Required
92R (10) Parachute Rigger
Equipment Condition
Fully Assembled.
References
WP 0005 00; WP 0007 00; WP 0010
00
INSPECT
Perform a technical/rigger-type inspection of the multi-loop line including buffer, sliding keeper, and fixed
keepers in accordance with WP 0007 00 and WP 0005 00 using the procedures in Table 1.
REPAIR
Repair sliding or fixed keepers as described below.
1. Sliding Keeper.
a.
Cut the stitching securing the buffer (2) to inside loop (3) and remove buffer (2).
b.
Slide the defective keeper off the multi-loop line.