TM 10-1670-296-20&P 0013 00
UNIT MAINTENANCE
ANCILLARY EQUIPMENT FOR LOW VELOCITY AIR DROP SYSTEMS (LVADS)
EXTRACTION FORCE TRANSFER COUPLING
0013 00-1
THIS TASK COVERS:
Inspect
Repair
Replace
Tools
Brush, Scrub, Household (Item 2, WP 0064 00)
File, Bastard (Item 8/9, WP 0064 00)
Knife (Item 17, WP 0064 00)
Straight Edge, 2-IN. (Item 45, WP 0064 00)
Tape Measure (Item 46, WP 0064 00)
Wrench, Open End, 1 1/16-IN. and 1 1/8-IN. (Item 54, WP 0064 00)
Wrench, Open End, 1 1/4-IN. and 1 5/16-IN (Item 52, WP 0064 00)
Wrench, Open End, 1
7/16-IN. and 1 5/8-IN (Item 56, WP 0064 00)
Wrench, Open End, 7/16-IN. (Item 50, WP 0064 00)
Equipment Condition
Fully Assembled.
References
WP 0005 00; WP 000800; WPs 0013 00 0019 00;
WPs 0068 00 WP 0073 00
Materials/Parts
Coupling, Extraction Force Transfer
(WP 0067 00)
Paint, Yellow Enamel (Item 23, WP
0125 00)
Pen, Ballpoint (Item 24, WP 0125 00)
Rag, Wiping (Item 25, WP 0125 00)
Personnel Required
92R (10) Parachute Rigger
INSPECT
Inspect the components of the coupling extraction force transfer in accordance with WP 0005 00 using the
procedures in Table1.
REPAIR
Disassemble Extraction Force Transfer Coupling (EFTC) as follows:
1. Remove cable assembly (2) from actuator (1) and latch assembly (7) as follows:
a.
Remove the locking pin (3) securing the housing cover to the actuator assembly and hinge the cover
open.
CAUTION
The stake assembly-adjusting collar (on the cable assembly) is preset
and staked by four setscrews. The collar position shall not be altered at
any time or under any condition.
b.
Using a suitable tool, loosen the locking nut (4) securing the cable assembly (2) housing to the
actuator assembly (1). Ensure the adjusting collar on the cable assembly is not disturbed during the
cable removal process.
c.
Remove the cotter pin and straight pin (5) securing the cable end clevis to the cable actuator and
remove the cable assembly from the actuator assembly.