TM 10-1670-296-20&P 0002 00
0002 00-20
Interconnect Cable. The interconnect cable is 10-feet long and connects one Y-connector to another Y-
connector. The interconnect cables may also be connected to each other without the Y-connector to
produce a much longer cable for varying missions.
FXC
P/N 811-00467
P1 TO "Y" CONNECTOR
P2 TO "Y" CONNECTOR
Main Cable. The main cable is a 50-foot cable used to connect the control box to the Y-connector.
FXC
P/N 811-00468
P1 TO "Y" CONNECTOR
P2 TO CONTROL BOX
Power Cable. The power cable connects the control box to the 28 VDC iron lung power outlet in the
aircraft. The C-5 and C-17 aircraft require adapter cables. The power cable is 20-feet long.
P2 TO AIRCRAFT POWER
P/N 811-00443
FXC CORPORATION
P1 TO CONTROL BOX
Cover. The cover is used to prevent metal-to-metal contact between the aircraft and the EPJD.