(8) Securing strap adapter ends (1). Replace damaged adapter end of securing strap as in (a) or (b) below.
(a) Cut a piece of webbing 2-1/2 inches longer than distance from adapter (2) to leading edge (3) of second
perpendicular web.
(b) Remove damaged end by cutting strap along edge (4) of harness, and remove adapter (2).
(c) Pass one end of replacement webbing through adapter (2), and fold end under 2-1/2 inches. Position
replacement on harness, and sew using size 3 thread, 5 to 8 stitches per inch and a type HD sewing machine.