TM 10-1670-305-23&P
POWER CABLE ASSEMBLY, MAIN/RESERVE
0019 00
UNIT MAINTENANCE
THIS WORK PACKAGE COVERS:
Removal, cleaning, inspection, repair, replacement, and installation
INITIAL SETUP
TOOLS
Screwdriver, Phillips, No. 2 (WP 0041 00, Item 7)
Wrench, Adjustable, 6 inch (WP 0041 00, Item 14)
Knife (WP 0041 00, Item 1)
MATERIALS
Isopropyl Alcohol (Anhydrous) (WP 0040 00, Item 1)
Cloth, Lint Free, Cleaning (WP 0040 00, Item 3)
GENERAL
This work package contains information and instructions to keep the AR2 power cable assembly
in good repair.
WARNING
Do not open or remove screws of AR2 housing. No internal maintenance is
authorized. Unauthorized disassembly may cause a malfunction which may
result in death of parachutist.
REMOVAL OF AR2 AND POWER CABLE ASSEMBLY
1. Ensure that the JUMP/OFF switch is OFF.
NOTE
If AR2 has not actuated, go to step 4.
2. If the AR2 has actuated, remove the AR2 and its power cable assembly from the parachute
by removing tacking, two screws, nuts and clamp. These parts (hardware) are accessories
attached to the parachute.
WARNING
Power cables are fitted with fixed eyes. After cocking the AR2 mechanism,
always re-inspect the eye for distortion or other damage which may cause it to
fail in use so that parachute may not deploy which may result in death of
parachutist. Discard and replace cables showing distortion or damage.
0019 00-1
Change 1