DISASSEMBLY OF POWER CABLE ASSEMBLY
1. Tap flange end of power housing on a table top to cause the cable seal retainer to protrude
from the power housing. If necessary, reach behind the cable seal retainer with a small
hooked tool to start it from the power housing so that it may be gripped with the fingers. Slow
withdrawal of cable seal retainer will usually bring power cable seal with it. If not, use same
tool to free power cable seal and remove it.
2. Pull ball of power cable through power cable seal and remove power cable from power
housing.
3. If power housing or power housing retainer must be replaced, first remove small split
retaining ring from flanged fitting using thin screwdriver, knife blade, or other suitable tool.
Insert the tool between the two layers of the ring and carefully run the tool around the fitting to
cam the ring out of its groove. Be careful not to damage or lose the retaining ring.
4. Remove the retaining ring, lanyard assembly, and power-housing retainer off the small end of
power housing.