TM 10-1670-305-23&P
0020 00-1
AUTOMATIC RIPCORD RELEASE, AR2
0020 00
JUMP/OFF SWITCH MAINTENANCE
THIS WORK PACKAGE COVERS:
Removal, cleaning, inspection, repair, replacement, and installation
INITIAL SETUP
TOOLS
Screwdriver, Slotted, 5/32-inch (WP 0041 00, Item 11)
MATERIALS
Isopropyl Alcohol (WP 0040 00, Item 1)
Lubricant, Antiseize (WP 0040 00, Item 2)
Cloth, Lint Free, Cleaning (WP 0040 00, Item 3)
GENERAL
This work package contains information and instructions to keep the AR2 JUMP/OFF switch in
good repair.
REMOVAL AND DISASSEMBLY OF JUMP/OFF SWITCH
CAUTION
Ensure that no foreign matter enters the AR2 through power cable openings,
push rod opening or screw holes.
1. If replacement is required, remove four screws (1) securing JUMP/OFF switch (2) and
remove JUMP/OFF switch (2). Move JUMP/OFF switch lever back and forth to access
screws (1).
2. Remove packing (3), push rod (4) and push rod spring (5) form body of unit.
NOTE
Before removing OFF and JUMP decals (6 and 7) observe where and how they
are positioned.