4-20. ASPSU -Replace (Cont)
4-20
INSPECTION
1.
Inspect sensor module for dents or cracks.
2.
Inspect new cutter module for dents or cracks. Insure that the cutter has not been fired.
END OF TASK
REASSEMBLY
1.
Insure safety tag and pin assembly is securely attached to the arming cable assembly.
2.
Remove and discard the shorting connector from the cutter module.
3.
Join the two modules together by alining modules using the beveled end of each and the retainer holes as guides.
Pressing the units together mates the electrical interface connector.
4.
Lock the two modules together by screwing down the four captive screws until tight.
NOTE
Installation of retainer line will not be performed until ASPSU on the HAARS.
END OF TASK