TM10-1670-286-20
EXTRACTION LINE PANEL PROCEDURES FOR C-17 GLOBEMASTER III 0018 00
STOWING 120/140-FOOT SIX LOOP EXTRACTION LINE TO EXTRACTION
LINE PANEL WITH EXTRACTION LINE BRIDLE ATTACHED
0018 00-5
Figure 5. Extraction Line Secured to Bottom Panel.
d. Beginning at upper left corner of bottom panel, make first S-fold/stow of extraction line and
secure with previously installed type I, ¼-inch cotton webbing (figure 6).
Figure 6. First S-Fold of Extraction Line.
e. Working from left to right, stow and secure extraction line on the bottom panel (8 stows on the
left and 8 on the right) with extraction line routed from bottom panel at lower left corner. Secure
extraction line using the type I, ¼-inch cotton webbing with a surgeons knot and locking knot
(figure 7).
NOTE
Stows must not extend beyond the edge of the panel.
4-Foot Mark
36 x38 IN Cotton
Muslin Cloth
Stow Ties
1,6, and 12
Extraction Line
Running End
First S-Fold
Bottom
Panel