TM10-1670-286-20
EXTRACTION LINE PANEL PROCEDURES FOR C-17 GLOBEMASTER III 0018 00
STOWING 120/140-FOOT SIX LOOP EXTRACTION LINE TO EXTRACTION
LINE PANEL WITH EXTRACTION LINE BRIDLE ATTACHED
0018 00-7
j. Ensure that the running end of the extraction line extends approximately 20-feet from the top
left corner of the top panel. Secure to stow loop on the left side with one turn, type I, ¼-inch
cotton webbing (figure 9).
Figure 9. Extraction Line Stowed to Top Panel.
4. Close Extraction Line Bag.
a. Place a 36 x 38-inch sheet of kraft paper (line separator) on top of stowed extraction line of
bottom panel (figure 10).
Figure 10. Line Separator in Place.
b. Fold top panel onto bottom panel and kraft paper (line separator). Align with upper
edge of bottom panel.
Top
Panel
20 FT of Extraction
Line Remaining
Line Separator
Top Panel
Extraction Line