TM 10-1670-286-20
EXTRACTION LINE PANEL 0005 00
STOWING 60-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE PANEL
0005 00-2
Figure 1. Layout for Extraction Line Panel and 60-FT. One Loop Extraction Line.
b. Install 16 retainer bands 8 on upper and 8 on lower row of stow loops.
c. Cut two 36-inch lengths of ½-inches wide tubular nylon webbing. Fold each length in
half and girth-hitch one to 6th stow loop from the left of upper and lower row of stow loops.
d. Cut four 6 x 16 inch pieces of cotton muslin cloth and four 36-inch lengths of ¼-inch
wide type I, cotton webbing and position at upper end of panel.
e. Place 60-foot, one loop extraction line on pack table. Locate and mark center point on extraction line.
f. Place extraction line lengthwise on panel with center mark aligned with center row of stow loops.