g. Install risers onto applicable connector links.
h. Using a 7/16-inch open-end wrench, tighten barrel nuts on connector links ¼ turn past
hand tight.
i.
Hand-tack each riser at connector link with one turn double nylon lacing tape.
j.
Perform follow-up procedure (WPs 0005 00 and 0006 00).
END OF WORK PACKAGE
Connector Link
Barrel Nut
Riser
Tacking