3. At lower end of housing, carefully cut and remove tacking from housing and housing cover. Remove
housing from cover.
4. Insert replacement ripcord housing through cover on container. Align upper end of housing with end
of housing cover and tack in place from underside of cover. Use four turns of tape, lacing and tying,
doubled. Secure with surgeons knot and locking knot. Trim free ends ¾-inch from knot.
Tacking
Four Turns Tape, Lacing