c. Using a punch and rawhide mallet or other non-steel impact device, spread grommet barrel by
hammering until barrel collar is rolled down smooth on washer. If grommet barrel splits during
hammering, remove and replace installed grommet with a serviceable item from stock. Repeat
the procedure in steps b. and c., above.
7. Tack AAD Junction plate to side flap using tape, lacing and tying, single. Starting on inside of side
flap, pass lacing tape up through one of the large round holes on wide end of AAD Junction plate.
Continue to tack through holes on that side of AAD Junction plate until reaching the stitching securing
the stiffener (6th small hole), then return stitching through holes back to starting point. Secure with
surgeons knot and locking knot. Trim free ends ¾-inch from knot.
8. Repeat step 7., on other side of AAD Junction plate.
9. Replace grommet IAW step 6., above.
END OF WORK PACKAGE
Tacking
Grommet