b. Center the No. 1 disassembly punch on the rolled end of the assembly pin. Strike several blows
with an 8- to 12-ounce hammer to break off the riveted head of the pin. Drive out the assembly
pin.
c. Keeping all components intact, remove female fitting from holder and place harness on a packing
table or other suitable surface with canopy release assembly facing up.
d. Remove assembly pin and safety clip (cover).
e. Retract slide and remove the actuator and lever assembly from the female fitting ensuring the
slide lip is placed as shown.
f.
Remove the slide.
Female Fitting
And Lever Assembly
Change 1