TM 10-1670-299-20&P
TO 14D1-2-470-2
NAVAIR 13-1-41
(3) Closing Flap Assembly. To replace this assembly (1) proceed as follows:
a Remove the reversible quick fit adapters (2) on the restraining loop assembly (3) from the vertical
restraint assembly (4). Remove the flap assembly (1) from the restraining loop assembly (3) but cutting the stitching (5)
holding these assemblies together.
b If the restraining loop assembly (3) is also being replaced, remove serviceable quick fit adapters (2)
and set aside.
c Fabricate new closing flap assembly (1) and restraining loop assembly (3), if required, as described
in Appendix E.
d Attach quick fit adapters (2) on restraining loop assembly (3) with new closing flap assembly (1) onto
vertical restraint assembly (4).
2-158