2-40.
Static Line (cont).
This task covers:
a.
Inspect
b.
Service
c. Repair
d.
Replace
(6)
Using a 2 1/2-inch of 1-inch wide, type I pressure-sensitive tape, serve the 1 1/2-inch long loop with one and
a half turns.
(7)
Stencil part numbers 11-1-219 on static line webbing using procedures in paragraph 2-19.
(8)
Install a serviceable riser clevis on 1 1/2-inch long clevis attaching loop according to original riser clevis
installation details.
Figure 2-65.2. Static Line Construction Details
Change 1 2-107