EXTRACTION LINE PANEL PROCEDURES FOR C-17 GLOBEMASTER III 0015 00
STOWING 160-FOOT ONE LOOP EXTRACTION LINE TO EXTRACTION LINE
PANEL WITH EXTRACTION BRIDLE ATTACHED
0015 00-6
c. Pass running ends of the 24-inch type I, ¼-inch cotton webbing around both plies and secure with
a surgeons knot and locking knot (figure 5).
Figure 5. Installing 24-inch Ties.
d. Make a positive tie at the 6th, 12th, and center top stow loops.
e. Beginning at upper left corner of panel, make first S-fold/stow of the extraction line and secure
with previously installed type I, ¼-inch cotton webbing ties (figure 6).
Figure 6. Positive Ties/First Stow.
Stow Loop Tie 1
3-Foot Mark
First Stow
Center Top Stow
Loop Tie
12th Stow Loop,
Positive Tie
6th Stow Loop,
Positive Tie