TM 10-1670-296-20&P 0044 00
0044 00-3
REPAIR
After a squib has been fired, refurbish prior to next use as follows:
1. Disassemble.
a.
If installed, remove squib cable (not shown) from squib (1).
b.
Using 1-inch wrench, remove squib (1) from housing (2). Remove and discard preformed packing
(3).
c.
Using piston stop/shear bolt retainer wrench, remove piston stop (4) and piston (5). Remove and
discard backup ring (6) and preformed packing (7).
d.
Using piston stop/shear bolt retainer wrench, remove the two shear bolt retainers (8) and shear bolt
(9) (shear bolt is removed from the bottom of the EPJD).
e.
Remove safety cap (10).
f.
Using T-handled hex driver, remove cross hole plug (11). Remove and discard preformed packing
(12).
g.
Remove screws (13) and retainer clamp (14) from latch (15).
h.
Remove latch retainer (16) from latch (15) and discard. If installed, remove keeper (17) from latch.
NOTE
Compressed air WILL NOT exceed 10psi.
2. Clean.
a.
Clean the inside bores (18) of housing (2) that contained the piston (5), and the squib (1). Use warm
water, mild liquid detergent, and large diameter bristle brush.
b.
Clean small diameter bore (19) used for cross hole plug (11). Use warm water, a mild liquid
detergent, and small diameter bristle brush.
c.
Rinse with clean water and dry thoroughly with a clean, lint-free cloth.
1
2
4
5
6
3
8
9
11
7
15
19
10
18
12
17
13
1614